Fronius 50kW Tauro

$9,014.50

SKU: INV-FRS50 Categories: , Tag:

50kW Inverter

10 Year Warranty

Description

Fronius are a world-leading inverter, welding and battery manufacturer that specializes in innovation. Whilst they’re not the cheapest unit on the market, a range of packaged features makes them versatile and highly intelligent. A Fronius Tauro 50 has WiFi or ethernet logging and is suitable for large scale commercial systems.

Fronius also have a 10-year warranty as an on-going special offer and have built a name that people can trust over many years of service in Australia. These inverters are also suitable for zero export (when combined with Fronius’ energy meter) and like SMA, are one of the most ‘battery ready’ inverters on the market.

WiFi and Ethernet System Monitoring

Smart Grid Ready

Open Data Communication

Energy Management Function

Export Limitation and Dynamic Peak Manager

Proactive Service

PV INPUT
Max DC Watts50,000
Max DC Voltage1000v
Nominal DC Voltage200v
MPPT Voltage Range400-870v
Max Input Current22
Max Short Circuit Current20
MPPT Trackers3
PV OUTPUT
Nominal AC Output50kVA
Max AC Current75.8/72.5
Max Efficiency98.5%
FEATURES
CommunicationsWifi/Ethernet Cable
ProtectionIP 65
Dimensions755x1109x346
Weight92kg
Warranty10 Year
FAULT CODES
STATE 102AC voltage too highFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid.Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
STATE 103AC voltage too low
STATE 105AC frequency too high
STATE 106AC frequency too low
STATE 107AC grid outside the permissible limits
STATE 108Stand-alone operation detected
STATE 112RCMU error
STATE 301Overcurrent (AC)Short-term interruption while feeding energy into the grid due to overcurrent in the inverter.

The inverter resumes with its startup routine.

Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
STATE 302Overcurrent (DC)
STATE 303The power stage set over the temperatureShort-term interruption while feeding energy into the grid due to over temperature.

The inverter resumes with its startup routine.

Purge openings for cooling air and heat sink if necessary; the fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer.
STATE 304Internal temperature too high
STATE 306LOW PV OUTPUT

The intermediate circuit voltage is too low for feeding energy into the grid

Short-term interruption while feeding energy into the grid.

The inverter resumes with its startup routine.

Fault is rectified automatically; if this STATE code occurs when there is sufficient insolation (sunlight) contact your solar power system installer.

IMPORTANT! Due to the low level of insolation (sunlight) early in the morning and in the evening, the STATE codes 306 (LOW PV OUTPUT) and 307 LOW PV VOLTAGE) are displayed routinely at these times of day. These STATE codes do not indicate any kind of fault.

STATE 307LOW PV VOLTAGE

DC input voltage is too low for feeding energy into the grid

STATE 308Intermediate circuit overvoltageShort-term interruption while feeding energy into the grid. The inverter resumes with its startup routine.Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
STATE 309DC input voltage MPPT 1 too high
STATE 313DC input voltage MPPT 2 too high
CodeDescriptionBehaviourRemedy
STATE 401No communication with the power stage set possibleThe inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid.If the STATE code is displayed all the time contact your local Fronius Service Partner
STATE 406The power stage set temperature sensor is faulty
STATE 407The internal temperature sensor is faulty
STATE 408DC feeding into the grid detected
STATE 412Fixed voltage mode has been selected instead of MPP voltage mode and the fixed voltage has been set to too low or too high a valueIf this STATE code persists contact your solar power system installer
STATE 415Safety cut out via option card or RECERBO has triggeredThe inverter is not feeding any energy into the grid.If the STATE code is displayed all the time contact your local Fronius Service Partner
STATE 416No communication is possible between the power stage set and the control systemThe inverter will automatically attempt to reconnect again and, if possible, will resume feeding energy into the grid.
STATE 417Hardware ID problem
STATE 419Unique ID conflict
STATE 421HID range error
STATE 425No communication is possible with the power stage set
STATE 426-428Possible hardware fault
STATE 431Software problemThe inverter is not feeding any energy into the grid.Carry out an AC reset (switch the AC circuit breaker off and on); update the firmware; if this status code is displayed all the time please contact your local Fronius Service Partner.
STATE 436Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced.The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid.Update the inverter firmware; if this status code is displayed all the time please contact your local Fronius Service Partner.
STATE 437The power stage set the problem
STATE 438Functional incompatibility (one or more PC boards in the inverter in the inverter are not compatible with each other, e.g. after a PC board has been replaced)
STATE 443Intermediate circuit voltage too low or asymmetricThe inverter is not feeding any energy into the grid.If the status code is displayed all the time contact your local Fronius Service Partners.
STATE 445Invalid limit value settingsThe inverter is not feeding any energy into the grid for safety reasons.Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner.
STATE 447Insulation faultIf this status code is displayed all the time: notify a local Fronius Service Partner
STATE 448The neutral conductor not connected
STATE 450Guard cannot be found
STATE 452Memory error detectedThe inverter will automatically attempt to connect again, and if possible, will resume feeding energy into the grid.If the STATE code is displayed all the time: notify your local Fronius Service Partner.
STATE 452Communication error between the processors
STATE 453Short-term grid voltage error
STATE 454Short-term grid frequency error
STATE 456The anti-islanding function is no longer implemented correctly
STATE 457Grid relay stickingThe inverter is not feeding any energy into the grid.Contact your local Fronius Service Partner.
STATE 459Error when recording the measuring signal for the insulation test
STATE 460The reference voltage source for the digital signal processor (DSP) is working out of tolerance
STATE 461Fault in the DSP data memory
STATE 462Error with DC feed monitoring routine
STATE 463Reversed AC polarity, AC connector inserted incorrectly
STATE 474RCMU sensor faultyIf this STATE code keeps recurring, contact your solar power system installer
STATE 475Solar panel ground fault, insulation fault (connection between solar panel and ground)
STATE 476Driver supply voltage too low
STATE 480, 481Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced)Update the inverter firmware; if the STATE code persists contact your local Fronius Service Partner
STATE 482Startup incompletePerform AC reset (turn AC circuit breaker off and on), and complete startup.
STATE 483Voltage UDC fixed on MPP2 string out of limitsCheck the MPP settings; if the status code is displayed all the time contact your local Fronius Service Partner
STATE 485CAN transmit buffer is fullCarry out an AC reset (turn the AC circuit breaker off and on), if the STATE code continues to be displayed notify your local Fronius Service Partner.
STATE 502Insulation error on the solar panelsA warning message is shown on the displayIf this STATE code keeps recurring, contact your solar power system installer.
STATE 509No energy fed into the grid in the past 24 hoursAcknowledge the STATE code; check whether all the conditions for the problem-free feeding of energy into the grid have been met. If the STATE code is displayed all the time: look out for further STATE codes.
STATE 515No communication with filter possibleIf the status code is displayed all the time notify your local Fronius Service Partner.
STATE 516No communication is possible with the storage unitStorage unit warning message.
STATE 517Derating caused by too high a temperatureWhen power derating occurs, a warning message is shown on the displayPurge cooling air openings and heat sink if necessary; the fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer.
STATE 522DC1 Input Voltage too lowThe DC voltage on input 1 of the inverter is too lowCheck voltage & polarity on input 1 of the inverter. If this STATE code keeps recurring please contact your solar power system installer.
STATE 523DC2 Input Voltage too lowThe DC voltage on input 2 of the inverter is too lowCheck voltage & polarity on input 2 of the inverter. Check MPP settings/voltage at the “Installer Menu Basic”. If this STATE code keeps recurring please contact your solar power system installer.
STATE 558Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced)Possible error displays or malfunctions on the inverterIf this STATE code keeps recurring contact your solar power system installer.
STATE 560Derating caused by over-frequencyThis STATE code is displayed when the grid frequency becomes excessively high. The inverter will then reduce its output. The status indicator will continue to be displayed until the inverter has returned to normal operation.As soon as the grid frequency is back within the permissible range and the inverter has returned to normal operation, the fault is rectified automatically. If this STATE code keeps recurring contact your solar power system installer.
STATE 566Arc detector switched off (e.g. during external arc monitoring)The STATE code is displayed every day until the arc detector is reactivated.No error, Confirm status code by pressing ‘Enter’.
STATE 567Grid Voltage Dependent Power Reduction is activeThis state code is a warning informing you that the Grid Voltage Dependent Power Reduction mode (GVDPR or Volt–Watt mode) has been activated and the inverter will continue to operate with reduced power output. This is because the grid voltage has exceeded 250Vac and the GVDPR has been enabled to try to reduce the voltage rise at the inverters terminals. This mode must be enabled by default in accordance with the latest Australian Standards.Acknowledge the status code; if this STATE 567 code keeps recurring contact your local solar power system installer.
STATE 705Conflict when setting the inverter number (e.g. number already assigned)Correct the inverter number via the setup menu
STATE 721EEPROM has been reinitialised or EEPROM is faultyA warning message is shown on the displayAcknowledge STATE code; If the STATE code is displayed all the time contact your local Fronius Service Partner
STATE 731Initialisation error – USB stick is not supportedCheck or replace the USB stick. Check the file system on the USB stick. If the STATE code is displayed all the time notify your local Fronius Service Partner.
STATE 732Overcurrent on a USB stick
STATE 733No USB stick connectedConnect or check the USB stick. If the STATE code is displayed all the time contact your local Fronius Service Partner.
STATE 734Update file not recognised or not presentCheck update file (e.g. for the correct file name). If the STATE code is displayed all the time contact your local Fronius Service Partner.
STATE 735The update file does not match the device, the update file is too oldA warning message appears on the display, update process is interrupted.Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. If the STATE code is displayed all the time contact your local Fronius Service Partner.
STATE 736Write or read error occurredA warning message is shown on the displayCheck the USB stick and the data contained on it or replace the USB stick.

Never unplug a USB stick if the ‘Data Transmission’ LED is still flashing or lit.

If the STATE code is displayed contact your local Fronius Service Partner.

STATE 738Log files cannot be saved (e.g. USB stick is write protected or full)tCreate storage space, remove write protection, and check or replace the USB stick if necessary.

If the STATE code is displayed all the time contact your local Fronius Service Partner.

STATE 743An error occurred during the update processRepeat the update process, and check the USB stick. If the STATE code is displayed all the time contact your local Fronius Service Partner.
STATE 745Update file corruptA warning message appears on the display, update process is interrupted.Redownload the firmware. If the STATE code is displayed all the time contact your local Fronius Service Partner.
STATE 751Time lostA warning message is shown on the displayReset the time and date on the inverter. Check the updated file (e.g. for the correct file name). If the STATE code is displayed all the time contact your local Fronius Service Partner.
STATE 752Real-Time Clock module communication error
STATE 757Hardware error in the Real Time Clock moduleThe error message is shown on the display; the inverter is not feeding any energy into the grid.If the STATE code is displayed all the time contact your local Fronius Service Partner.
STATE 758Internal error: Real Time Clock module is in emergency modeTime may be inaccurate or lost (feeding energy into the grid normally)..
STATE 766Emergency power de-rating has been activatedThe error message is shown on the display.

Additional information

Weight92 kg
Height

755

Length

346

Manufacturer Bundle

Fronius

Width

1109