×

6kW Solar PV System | Fronius and Q Cell

25.2kWh per day 9198kWh per year

Fronius Inverter
Q Cell Panels
Clenergy Rail Kit
ABB Materials Kit


10 Year Inverter Warranty
25 Year Panel Warranty
25 Year Performance Guarantee
5 Year Installation Warranty and Service Guarantee
5 Year Production Guarantee
SKU
SOL-FR6-QC6

As low as $6,536.94

Customise 6kW Solar PV System | Fronius and Q Cell
1 x ABB Solar Materials Kit Dual Tracker   + $432.77

* Required Fields

Your Customisation
6kW Solar PV System | Fronius and Q Cell
6kW Solar PV System | Fronius and Q Cell

In stock

$4,312.81

Summary

    Aimed primarily at the residential market, this 6kW Fronius and LG solar system will provide for day time usage and also and cover items such as hot water systems or swimming pools.


    Fronius is a world leading inverter, welding and battery manufacturer that specializes in innovation. While they're not the cheapest unit on the market, a range of packaged features makes them highly intelligent. A Fronius inverter has wireless logging and a programmable smart relay. The relay can be used to switch excess production to items such as electric hot water systems and is far more accurate than a traditional timer-relay combination.

    Fronius offers an industry-leading 10-year warranty as standard. Their product range includes cost-effective options for both consumption metering and energy management.


    Hanwha Qcells Co. Ltd., is one of the world´s largest and most recognized photovoltaic manufacturers for its high-quality, high-efficiency solar cells and modules. It is headquartered in Seoul, South Korea (Global Executive HQ) and Thalheim, Germany (Technology & Innovation HQ). Apart from continually setting the standards for quality, Q Cells has focused on setting up a national installer network showing that they understand not just what makes a panel, but also every aspect of what goes into a high performing and long lasting solar installation.

    This premium range combines high-quality components aimed at achieving the longest lifespan possible. These combinations achieve payback in medium terms but will generate for longer periods with less maintenance.

    PV INPUT  
    Max DC Watts
    Max DC Voltage 1000v
    Feed-in start voltage 80v
    MPPT Voltage Range 80-800v
    Max Input Current
    Max Short Circuit Current
    MPPT Trackers 2
       
    PV OUTPUT  
    Nominal AC Output 5kVA
    Technology Transformerless
    Max Efficiency 97.8%
       
    FEATURES  
    Power factor 0.70 - 1 ind/cap
    Protection IP 65
    Dimensions 645x431x204
    Weight 21.5kg
    Warranty 10 Year
       
       

    Q CELL PANEL  
    Format 1879mm × 1045mm × 32mm (including frame)
    Weight 22.0kg
    Front Cover 3.2mm thermally pre-stressed glass with anti-reflection technology
    Back Cover Composite film
    Frame Black anodised aluminium
    Cell 6 × 22 monocrystalline Q.ANTUM solar half cells
    Junction box 53-101mm × 32-60mm × 15-18 mm Protection class IP67, with bypass diodes
    Cable 4mm2 Solar cable; (+) ≥1250mm, (−) ≥1250mm
    Connector Stäubli MC4; IP68


    FAULT CODES
    Code Description Behaviour Remedy
    STATE 102 AC voltage too high Following careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
    STATE 103 AC voltage too low
    STATE 105 AC frequency too high
    STATE 106 AC frequency too low
    STATE 107 AC grid outside the permissible limits
    STATE 108 Stand alone operation detected
    STATE 112 RCMU error
    STATE 301 Overcurrent (AC) Short-term interruption while feeding energy into the grid due to over current in the inverter.

    The inverter resumes with its startup routine.

    Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
    STATE 302 Overcurrent (DC)
    STATE 303 Power stage set over temperature Short term interruption while feeding energy into the grid due to over temperature.

    The inverter resumes with its startup routine.

    Purge openings for cooling air and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer.
    STATE 304 Internal temperature too high
    STATE 306 LOW PV OUTPUT

    Intermediate circuit voltage too low for feeding energy into the grid

    Short term interruption while feeding energy into the grid.

    The inverter resumes with its startup routine.

    Fault is rectified automatically; if this STATE code occurs when there is sufficient insolation (sunlight) contact your solar power system installer.

    IMPORTANT! Due to the low level of insolation (sunlight) early in the morning and in the evening, the STATE codes 306 (LOW PV OUTPUT) and 307 LOW PV VOLTAGE) are displayed routinely at these times of day. These STATE codes do not indicate any kind of fault.

    STATE 307 LOW PV VOLTAGE

    DC input voltage too low for feeding energy into the grid

    STATE 308 Intermediate circuit overvoltage Short term interruption while feeding energy into the grid. The inverter resumes with its startup routine. Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
    STATE 309 DC input voltage MPPT 1 too high
    STATE 313 DC input voltage MPPT 2 too high
    Code Description Behaviour Remedy
    STATE 401 No communication with power stage set possible The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. If the STATE code is displayed all the time contact your local Fronius Service Partner
    STATE 406 Power stage set temperature sensor faulty
    STATE 407 Internal temperature sensor faulty
    STATE 408 DC feeding into the grid detected
    STATE 412 Fixed voltage mode has been selected instead of MPP voltage mode and the fixed voltage has been set to too low or too high a value If this STATE code persists contact your solar power system installer
    STATE 415 Safety cut out via option card or RECERBO has triggered The inverter is not feeding any energy into the grid. If the STATE code is displayed all the time contact your local Fronius Service Partner
    STATE 416 No communication possible between power stage set and control system The inverter will automatically attempt to reconnect again and, if possible, will resume feeding energy into the grid.
    STATE 417 Hardware ID problem
    STATE 419 Unique ID conflict
    STATE 421 HID range error
    STATE 425 No communication possible with the power stage set
    STATE 426-428 Possible hardware fault
    STATE 431 Software problem The inverter is not feeding any energy into the grid. Carry out an AC reset (switch the AC circuit breaker off and on); update the firmware; if this status code is displayed all the time please contact your local Fronius Service Partner.
    STATE 436 Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced. The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. Update the inverter firm ware; if this status code is displayed all the time please contact your local Fronius Service Partner.
    STATE 437 Power stage set problem
    STATE 438 Functional incompatibility (one or more PC boards in the inverter in the inverter are not compatible with each other, e.g. after a PC board has been replaced)
    STATE 443 Intermediate circuit voltage too low or asymmetric The inverter is not feeding any energy into the grid. If the status code is displayed all the time contact your local Fronius Service Partners.
    STATE 445 Invalid limit value settings The inverter is not feeding any energy into the grid for safety reasons. Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner.
    STATE 447 Insulation fault If this status code is displayed all the time: notify a local Fronius Service Partner
    STATE 448 Neutral conductor not connected
    STATE 450 Guard cannot be found
    STATE 452 Memory error detected The inverter will automatically attempt to connect again, and if possible, will resume feeding energy into the grid. If the STATE code is displayed all the time: notify your local Fronius Service Partner.
    STATE 452 Communication error between the processors
    STATE 453 Short term grid voltage error
    STATE 454 Short term grid frequency error
    STATE 456 Anti-islanding function is no longer implemented correctly
    STATE 457 Grid relay sticking The inverter is not feeding any energy into the grid. Contact your local Fronius Service Partner.
    STATE 459 Error when recording the measuring signal for the insulation test
    STATE 460 Reference voltage source for the digital signal processor (DSP) is working out of tolerance
    STATE 461 Fault in the DSP data memory
    STATE 462 Error with DC feed monitoring routine
    STATE 463 Reversed AC polarity, AC connector inserted incorrectly
    STATE 474 RCMU sensor faulty If this STATE code keeps recurring, contact your solar power system installer
    STATE 475 Solar panel ground fault, insulation fault (connection between solar panel and ground)
    STATE 476 Driver supply voltage too low
    STATE 480, 481 Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) Update the inverter firmware; if the STATE code persists contact your local Fronius Service Partner
    STATE 482 Startup incomplete Perform AC reset (turn AC circuit breaker off and on), complete startup.
    STATE 483 Voltage UDC fixed on MPP2 string out of limits Check the MPP settings; if the status code is displayed all the time contact your local Fronius Service Partner
    STATE 485 CAN transmit buffer is full Carry out an AC reset (turn AC circuit breaker off and on), if the STATE code continues to be displayed notify your local Fronius Service Partner.
    STATE 502 Insulation error on the solar panels Warning message is shown on the display If this STATE code keeps recurring, contact your solar power system installer.
    STATE 509 No energy fed into the grid in the past 24 hours Acknowledge STATE code; check whether all the conditions for the problem free feeding of energy into the grid have been met. If the STATE code is displayed all the time: look out for further STATE codes.
    STATE 515 No communication with filter possible If the status code is displayed all the time notify your local Fronius Service Partner.
    STATE 516 No communication possible with the storage unit Storage unit warning message.
    STATE 517 Derating caused by too high a temperature When power derating occurs, a warning message is shown on the display Purge cooling air openings and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer.
    STATE 522 DC1 Input Voltage too low The DC voltage on input 1 of the inverter is too low Check voltage & polarity on input 1 of the inverter. If this STATE code keeps recurring please contact your solar power system installer.
    STATE 523 DC2 Input Voltage too low The DC voltage on input 2 of the inverter is too low Check voltage & polarity on input 2 of the inverter. Check MPP settings / voltage at the “Installer Menu Basic”. If this STATE code keeps recurring please contact your solar power system installer.
    STATE 558 Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) Possible error displays or malfunction on the inverter If this STATE code keeps recurring contact your solar power system installer.
    STATE 560 Derating caused by over-frequency This STATE code is displayed when the grid frequency becomes excessively high. The inverter will then reduce its output. The status indicator will continue to be displayed until the inverter has returned to normal operation. As soon as the grid frequency is back within the permissible range and the inverter has returned to normal operation, the fault is rectified automatically. If this STATE code keep recurring contact your solar power system installer.
    STATE 566 Arc detector switched off (e.g. during external arc monitoring) The STATE code is displayed every day until the arc detector is reactivated. No error, Confirm status code by pressing ‘Enter’.
    STATE 567 Grid Voltage Dependent Power Reduction is active This state code is a warning informing you that the Grid Voltage Dependent Power Reduction mode (GVDPR or Volt – Watt mode) has been activated and the inverter will continue to operate with reduced power output. This is because the grid voltage has exceeded 250Vac and the GVDPR has been enabled to try to reduce the voltage rise at the inverters terminals. This mode must be enabled by default in accordance with the latest Australian Standards. Acknowledge status code; if this STATE 567 code keeps recurring contact your local solar power system installer.
    STATE 705 Conflict when setting the inverter number (e.g. number already assigned) Correct the inverter number via the setup menu
    STATE 721 EEPROM has been reinitialised or EEPROM is faulty Warning message is shown on the display Acknowledge STATE code; If the STATE code is displayed all the time contact your local Fronius Service Partner
    STATE 731 Initialisation error – USB stick is not supported Check or replace USB stick. Check the file system on the USB stick. If the STATE code is displayed all the time notify your local Fronius Service Partner.
    STATE 732 Over current on USB stick
    STATE 733 No USB stick connected Connect or check the USB stick. If STATE code is displayed all the time contact your local Fronius Service Partner.
    STATE 734 Update file not recognised or not present Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner.
    STATE 735 Update file does not match the device, update file too old Warning message appears on the display, update process is interrupted. Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. If STATE code is displayed all the time contact your local Fronius Service Partner.
    STATE 736 Write or read error occurred Warning message is shown on the display Check USB stick and the data contained on it or replace USB stick.

    Never unplug a USB stick if the ‘Data Transmission’ LED is still flashing or lit.

    If the STATE code is displayed all the contact your local Fronius Service Partner.

    STATE 738 Log file cannot be saved (e.g. USB stick is write protected or full)t Create storage space, remove write protection, check or replace USB stick if necessary.

    If STATE code is displayed all the time contact your local Fronius Service Partner.

    STATE 743 Error occurred during update process Repeat the update process, check USB stick. If STATE code is displayed all the time contact your local Fronius Service Partner.
    STATE 745 Update file corrupt Warning message appears on the display, update process is interrupted. Redownload the firmware. If STATE code is displayed all the time contact your local Fronius Service Partner.
    STATE 751 Time lost Warning message is shown on the display Reset the time and date on the inverter. Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner.
    STATE 752 Real Time Clock module communication error
    STATE 757 Hardware error in the Real Time Clock module Error message is shown on the display; the inverter is not feeding any energy into the grid. If STATE code is displayed all the time contact your local Fronius Service Partner.
    STATE 758 Internal error: Real Time Clock module is in emergency mode Time may be inaccurate or lost (feeding energy into the grid normal)..
    STATE 766 Emergency power de-rating has been activated Error message is shown on the display.
    More Information
    Manufacturer Fronius
    Weight N/A
    Length No
    Width No
    Height No
    Part Number No

    Product Information Sheet

    docx
    (Size: 291.7 KB)
    Fronius - How to Update Wifi
    pdf
    (Size: 45.6 KB)
    Fronius Access Code
    pdf
    (Size: 1.7 MB)
    Fronius Commissioning Manual
    pdf
    (Size: 3 MB)
    Fronius Data Manager 2 Manual
    pdf
    (Size: 20.8 KB)
    Fronius Data Network Specification
    pdf
    (Size: 2.7 MB)
    Fronius Inverters Datasheet
    pdf
    (Size: 766 KB)
    Fronius Modbus communication
    pdf
    (Size: 919.2 KB)
    Fronius Primo Operating Manual
    pdf
    (Size: 1.4 MB)
    Fronius Reactive Power and Grid Voltage Settings Guide
    pdf
    (Size: 69.6 KB)
    Fronius Warranty
    pdf
    (Size: 146.1 KB)
    Fronius Warranty - service-process-overview-fronius-australia
    pdf
    (Size: 965.1 KB)
    Fronius Zero Export Guide
    docx
    (Size: 4.8 MB)
    SOLAR Warranty Certificate Template
    * Please Login or Register to download this file.
    Write Your Own Review
    You're reviewing:6kW Solar PV System | Fronius and Q Cell
    Your Rating
    We found other products you might like!